C.9 MEMOBUS/Modbus Data Table
Register No.
Alarm Contents 5
bit 0
bit 1
bit 2
bit 3
bit 4
00CBH
bit 5
bit 6
bit 7
bit 8
bit 9
bit A to F
Alarm Contents 6
bit 0
bit 1
bit 2
bit 3
bit 4
00CCH
bit 5 to 6
bit 7
bit 8 to B
bit C
bit D
bit E
bit F
00CDH
Reserved
bit 0, 1
bit 2
bit 3
00CEH
bit 4
bit 5
bit 6
bit 7
00CFH
Reserved
CPF Contents 1
bit 0, 1
bit 2
bit 3
bit 4, 5
bit 6
bit 7
00D0H
bit 8
bit 9, A
bit B
bit C
bit D
bit E
bit F
528
Contents
SI-T3 Watchdog Error (E5)
SI-T3 Station Address Setting Error (AEr)
SI-T3 Comm. Cycle Setting Error (CyC)
High Current Alarm (HCA)
Cooling Fan Maintenance Time (LT-1)
Soft Charge Bypass Relay Maintenance Time (LT-2)
Reserved
SI-S EEPROM Error (EEP)
External Fault 1 (input terminal S1) (EF1)
External Fault 2 (input terminal S2) (EF2)
Reserved
Output Voltage Detection Fault (VoF)
IGBT Maintenance Time (90%) (TrPC)
Capacitor Maintenance Time (LT-3)
IGBT Maintenance Time (50%) (LT-4)
Braking Transistor Overload Fault (boL)
Reserved
Motor Overheat (NTC Input) (oH5)
Reserved
Thermistor Disconnect (THo)
Underload Detection 6 (UL6)
Waiting for Run (wRUn)
Reserved
Reserved
Time Not Set (TIM)
Battery Low (bAT)
Time Deviation Error (TdE)
Reserved
Emergency Override FWD (EoF)
Emergency Override REV (Eor)
Reserved
A/D Conversion Error (CPF02)
PWM Data Fault (CPF03)
Reserved
EEPROM Memory Data Error (CPF06)
Terminal Board Connection Error (CPF07)
EEPROM Serial Communications Fault (CPF08)
Reserved
RAM Fault (CPF11)
FLASH Memory Fault (CPF12)
Watchdog Circuit Exception (CPF13)
Control Circuit Fault (CPF14)
Reserved
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual