B.7 F: Communication Options
No.
(Addr.
Name
Hex)
F6-51
DeviceNet Communication
(3C2)
Speed
F6-52
DeviceNet PCA Setting
(3C3)
F6-53
DeviceNet PPA Setting
(3C4)
F6-54
DeviceNet Idle Mode Fault
(3C5)
Detection
F6-55
DeviceNet Baud Rate
(3C6)
Monitor
F6-56
DeviceNet Speed Scaling
(3D7)
F6-57
DeviceNet Current Scaling
(3D8)
F6-58
DeviceNet Torque Scaling
(3D9)
F6-59
DeviceNet Power Scaling
(3DA)
F6-60
DeviceNet Voltage Scaling
(3DB)
F6-61
DeviceNet Time Scaling
(3DC)
F6-62
DeviceNet Heartbeat
(3DD)
Interval
F6-63
DeviceNet Network MAC
(3DE)
ID
F6-64 to
F6-71
Reserved
(3DF to
3C8)
F6-72
(081B)
PowerLink Node Address
<1>
F6-75
(0B20)
P1-N2 Protocol Select
<3>
F6-76
(0B20)
P1-N2 Comm Fault
<3>
F6-77
(0B22)
P1-N2 Comm Fault Time
<3>
F6-78
(0B23)
P1-N2 Node Address
<3>
450
0: 125 kbps
1: 250 kbps
2: 500 kbps
3: Adjustable from network
4: Detect automatically
Sets the format of the data set from the DeviceNet master to the drive.
Sets the format of the data set from the drive to the DeviceNet master.
0: Enabled
1: Disabled, no fault detection
<1>
2: Vendor Specific
<1>
3: Forward
<1>
4: Reverse
Verifies the baud rate running on the network.
0: 125 kbps
1: 250 kbps
2: 500 kbps
Sets the scaling factor for the speed monitor in DeviceNet.
Sets the scaling factor for the output current monitor in DeviceNet.
Sets the scaling factor for the torque monitor in DeviceNet.
Sets the scaling factor for the power monitor in DeviceNet.
Sets the scaling factor for the voltage monitor in DeviceNet.
Sets the scaling factor for the time monitor in DeviceNet.
Sets the heartbeat interval for DeviceNet communications.
Saves and monitors settings 0 to 63 of F6-50 (DeviceNet MAC Address).
Reserved for Dynamic I/O Assembly Parameters.
Reserved.
Selects the protocol for the SI-J3 option card.
1: N2
2: P1
0: Disabled
1: Enabled
Sets the length of time before clearing a communication fault.
Sets the network node address.
Description
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
Values
Page
Default: 4
203
Range: 0 to 4
Default: 21
Min.: 0
203
Max.: 255
Default: 71
Min.: 0
203
Max.: 255
Default: 0
203
Range: 0 to 4
Default: 0
204
Range: 0 to 2
Default: 0
Min.: -15
204
Max.: 15
Default: 0
Min.: -15
204
Max.: 15
Default: 0
Min.: -15
204
Max.: 15
Default: 0
Min.: -15
204
Max.: 15
Default: 0
Min.: -15
204
Max.: 15
Default: 0
Min.: -15
204
Max.: 15
Default: 0
Min.: 0
204
Max.: 10
Default: 63
Min.: 0
204
Max.: 63
Default: 2
Range: 1, 2
Default: 1
Range: 0, 1
Default: 2.0 s
Min.: 0.0
Max.: 10.0
Default: 1
Range: 0 to 255