YASKAWA P1000 Technical Manual page 352

Models: 200 v class: 3/4 to 175 hp nd 400 v class: 3/4 to 1000 hp nd 600 v class: 1 to 250 hp nd
Hide thumbs Also See for P1000:
Table of Contents

Advertisement

7.4 Drive Cooling Fans
A – Back
Figure 7.10 Cooling Fan Power Supply Connectors: 2A0110, 2A0138, 4A0058, 4A0072, 5A0041, and 5A0052
3.
Install the replacement fan into the drive.
Figure 7.11 Install the Cooling Fan: 2A0110, 2A0138, 4A0058, 4A0072, 5A0041, and 5A0052
4.
Tilt up the back end of the fan finger guard and slide the fan finger guard into the opening near the front of the drive,
then guide the fan finger guard into place.
Figure 7.12 Reattach the Fan Cover: 2A0110, 2A0138, 4A0058, 4A0072, 5A0041, and 5A0052
5.
Press in on the hooks of the left and right sides of the fan cover and guide the fan finger guard until it clicks into place.
Figure 7.13 Reattach the Fan Finger Guard: 2A0110, 2A0138, 4A0058, 4A0072, 5A0041, and 5A0052
6.
Turn on the power supply and set o4-03 to 0 to reset the Maintenance Monitor cooling fan operation time.
352
B – Front
Insert the fan at an angle so that
it tilts towards the front of the
drive. Next press down on the
back of the fan that still protrudes
from the drive so that the fan
snaps into place.
Insertion area
Front of drive
Back of drive
Cross-Section
Fan finger guard
Back of drive
Hook
Front of drive
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
A
B
Hook

Hide quick links:

Advertisement

Table of Contents
loading