B.16 Defaults by Drive Model
No.
o2-04
E2-11
b3-04
V/f Gain during Speed Search
b3-06
Output Current 1 during Speed Search
Output Current 2 during Speed Search
b3-07
(Speed Estimation Type)
b3-26
Start Speed Search Select
b8-03
Energy Saving Control Filter Time Constant
b8-04
Energy Saving Coefficient Value
C5-17
Motor Inertia
C6-02
Carrier Frequency Selection
E2-01
Motor Rated Current
E2-02
Motor Rated Slip
E2-03
Motor No-Load Current
E2-05
Motor Line-to-Line Resistance
E2-06
Motor Leakage Inductance
E2-10
Motor Iron Loss for Torque Compensation
L2-02
Momentary Power Loss Ride-Thru Time
L2-03
Momentary Power Loss Minimum Baseblock Time
L2-04
Momentary Power Loss Voltage Recovery Time
L3-24
Motor Acceleration Time for Inertia Calculations
L8-02
Overheat Alarm Level
L8-35
Installation Method Selection
L8-38
Carrier Frequency Reduction Selection
n1-03
Hunting Prevention Time Constant
500
Name
Model CIMR-Po
Drive Model Selection
Motor Rated Power
Unit
5A0017
Hex.
CA
11
kW (HP)
(15)
%
100
0.5
s
0.5
172
2
0.053
kgm
7
A
17
Hz
1.7
A
5.1
Ω
1.17
%
19.6
W
385
s
1
s
1
s
0.9
s
0.27
°C
120
2
2
ms
10
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
Default Settings
5A0022
5A0027
CC
CD
15
18.5
(20)
(25)
100
100
0.5
0.5
0.5
0.5
154
140
0.076
0.138
7
7
22
27
1.6
1.67
6.6
8.1
0.9
0.66
17.2
20.1
440
508
2
2
1.2
1.2
1
1
0.24
0.32
120
115
2
2
2
2
10
10
5A0032
CE
22
(30)
100
0.5
0.5
129
0.165
7
32
1.7
9.6
0.52
23.5
586
2
1.2
1
0.36
115
2
2
10