5.10 o: Operator Related Settings
o1-22: Mechanical Gear Ratio
Sets the gear ratio of the mechanical gear.
No.
o1-22
<1> The setting range changes depending on drive software versions.
PRG: 7017 or earlier: 0.10 to 50.00
PRG: 7200 or later: 0.10 to 100.00
o1-23: HBB Non Display Select
Shows or hides the HBB command on the digital operator while the safety signal is being input.
No.
o1-23
<1>
<1> Available in drive software versions PRG: 7200 or later.
Setting 0: Show HBB
HBB is displayed on the digital operator while the safety signal is being input.
Setting 1: Hide HBB
HBB is not displayed on the digital operator while the safety signal is being input.

◆ o2: Digital Operator Keypad Functions

These parameters determine the functions assigned to the operator keys.
o2-01: LO/RE (LOCAL/REMOTE) Key Function Selection
Parameter o2-01 determines whether the LO/RE key on the digital operator will be enabled or not for switching between
LOCAL and REMOTE.
No.
o2-01
Setting 0: Disabled
The LO/RE key is disabled.
Setting 1: Enabled
The LO/RE switches between LOCAL and REMOTE operation. Switching is possible during stop only. When LOCAL is
selected, the LED indicator on the LO/RE key will light up.
o2-02: STOP Key Function Selection
Determines if the STOP key on the digital operator can still be used to stop drive operation when the drive is being
controlled from a remote source (i.e., not from digital operator).
No.
o2-02
Setting 0: Disabled
Setting 1: Enabled
The STOP key will terminate drive operation even if the Up/Down command source is not assigned to the digital
operator. Cycle the Up/Down command to restart the drive if the drive has been stopped by pressing the STOP key.
252
Parameter Name
Mechanical Gear Ratio
Parameter Name
HBB Non Display Select
Parameter Name
LO/RE Key Function Selection
Parameter Name
STOP Key Function Selection
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
Setting Range
Determined by A1-02
<1>
Setting Range
0 or 1
Setting Range
0 or 1
Setting Range
0 or 1
Default
Default
0
Default
0
Default
0

Hide quick links: