Navigating The Drive And Programming Modes - YASKAWA P1000 Technical Manual

Models: 200 v class: 3/4 to 175 hp nd 400 v class: 3/4 to 1000 hp nd 600 v class: 1 to 250 hp nd
Hide thumbs Also See for P1000:
Table of Contents

Advertisement

u

Navigating the Drive and Programming Modes

The drive is set to operate in Drive Mode when it is first powered up. Switch between display screens by using the
keys.
Mode
Contents
Frequency
Power Up
Reference
(default)
Drive Mode
Monitor Display
Verify Menu
Setup Group
Programming
Mode
Parameter
Setting Mode
Auto-Tuning
Mode
Frequency
Drive Mode
Reference
n
Drive Mode Details
The following actions are possible in the Drive Mode:
• Run and stop the drive
• Monitor the operation status of the drive (frequency reference, output frequency, output current, output voltage, etc.)
• View information on an alarm
• View a history of alarms that have occurred
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
4.3 The Drive, Programming, and Clock Adjustment Modes
Operator Display
This display screen allows the user to monitor and change the frequency reference while
- MODE -
DRV
Rdy
the drive is running.
FREF (OPR)
Modes on page
U1-01= 0.00Hz
U1-02= 0.00Hz
LSEQ
Note:
U1-03= 0.00A
LREF
JOG
FWD
FWD/REV
- MODE -
DRV
Rdy
Monitor Menu
Lists the monitor parameters (Uo-oo parameters) available in the drive.
U1-01= 0.00Hz
Press the Enter Key and then use the Up, Down, ESC, and Reset keys to navigate through
U1-02= 0.00Hz
LSEQ
the drive monitors.
U1-03= 0.00A
LREF
JOG
FWD
FWD/REV
- MODE -
PRG
Modified Consts
Lists all parameters that have been edited or changed from default settings.
Modified
Verifying Parameter Changes: Verify Menu on page
X Parameters
HELP
FWD
DATA
- MODE -
PRG
A select list of parameters necessary to get the drive operating quickly.
Quick Setting
Using the Setup Groups on page
Note:
HELP
FWD
DATA
- MODE -
PRG
Programming
Allows the user to access and edit all parameter settings.
page
431.
HELP
FWD
DATA
- MODE -
PRG Rdy
Auto-Tuning
Motor parameters are calculated and set automatically.
AUTO
page
129.
HELP
FWD
DATA
- MODE -
DRV
Rdy
FREF (OPR)
U1-01= 0.00Hz
Returns to the frequency reference display screen.
U1-02= 0.00Hz
LSEQ
U1-03= 0.00A
LREF
JOG
FWD
FWD/REV
Description
Refer to The Drive, Programming, and Clock Adjustment
114.
Use parameter o1-02 to select the data displayed when the drive is first
powered up. Setting parameter A1-02 to 6 or 7 (AOLV/PM or CLV/PM
control) will change display units to percent.
121.
Parameters listed in the Setup Group differ depending the Application
Preset in parameter A1-06.
Refer to Application Selection on page
and
Refer to
120.
Refer to
126.
Refer to Parameter List on
Refer to Auto-Tuning on
117
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents