RDP Commands
ip router-discovery interface min-advertisement-interval
Configures the minimum time, in seconds, RDP allows between each advertisement packet the router
transmits on the specified interface.
ip router-discovery interface name min-advertisement-interval seconds
Syntax Definitions
name
seconds
Defaults
parameter
seconds
Platforms Supported
OmniSwitch 6250
Usage Guidelines
•
The RDP interface minimum advertisement time is not active unless RDP is enabled on the switch and
the specified interface is also enabled.
•
Do not specify a value for the minimum advertisement interval that is greater than the value specified
for the maximum advertisement interval. To set the maximum advertisement interval value, use the ip
router-discovery interface max-advertisement-interval command.
•
Note that the minimum and maximum advertisement values define an interval of time in which RDP
transmits advertisement packets. RDP transmits packets at random times within this interval, waiting
no longer than the maximum time specified and no sooner than the minimum time specified before the
next transmission.
Examples
-> ip router-discovery interface Marketing min-advertisement-interval 20
-> ip router-discovery interface Accounting min-advertisement-interval 3
Release History
Release 6.6.1; command was introduced.
OmniSwitch 6250 CLI Reference Guide
The IP interface name that was defined at the time the IP interface was
configured.
The minimum amount of time allowed before the next advertisement
occurs. The range is 3 seconds to the value set for the maximum adver-
tisement interval.
default
0.75 * maximum advertisement interval
November 2009