Udld Probe-Timer - Alcatel-Lucent OmniSwitch 6250 Cli Reference Manual

Hide thumbs Also See for OmniSwitch 6250:
Table of Contents

Advertisement

UDLD Commands

udld probe-timer

Configures the probe-message advertisement timer on a specific port, a range of ports, or all the ports.
Probe-messages are transmitted periodically after this timer expires.
udld port [slot/port[-port2]] probe-timer seconds
no udld port [slot/port[-port2]] probe-timer
Syntax Definitions
slot/port
port2
seconds
Defaults
parameter
seconds
Platforms Supported
OmniSwitch 6250-Metro Models
Usage Guidelines
Use the no form of this command to reset the probe-message timer to the default value. Note that it is
not necessary to specify the probe-message interval to reset it.
The UDLD protocol must be enabled before using this command.
Configure probe-advertisement timer with values varying in a range of 12-18 seconds for better
convergence time and to avoid burst of probe advertisements.
Examples
-> udld probe-timer 20
-> udld port 1/3 probe-timer 16
-> udld port 1/8-21 probe-timer 18
-> no udld probe-timer
-> no udld port 1/3 probe-timer
Release History
Release 6.6.1; command was introduced.
OmniSwitch 6250 CLI Reference Guide
The slot number for the module and the physical port number on that
module (e.g., 3/1 specifies port 1 on slot 3).
The last port number in a range of ports that you want to configure on
the same slot (e.g, 3/1-4 specifies ports 1-4 on slot 3).
The probe-message transmission interval, in seconds (7-90).
default
15
November 2009
page 27-7