Show Snmp Engineid - D-Link DGS-1510/ME Series Reference Manual

Table of Contents

Advertisement

DGS-1510/ME Series Metro Ethernet Switch CLI Reference Guide
Format
config snmp engineID <snmp_engineID 10-64>
Parameters
<snmp_engineID 10-64> - Enter the SNMP engine ID here. It is octet string type. It accepts the hex number
directly. This value must be between 10 and 64.
Restrictions
Only Administrators can issue this command.
Example
To configure SNMP engine ID to "1023457890":
DGS-1510-28XMP/ME:admin# config snmp engineID 1023457890
Command: config snmp engineID 1023457890
Success.
DGS-1510-28XMP/ME:admin#

67-17 show snmp engineID

Description
This command is used to display the identification of the SNMP engine on the Switch. The default value is
suggested in RFC2271. The very first bit is 1, and the first four octets are set to the binary equivalent of the agent's
SNMP management private enterprise number as assigned by IANA, D-Link is 171. The fifth octet is 03 to
indicates the rest is the MAC address of this device. The 6th –11th octets is MAC address.
Format
show snmp engineID
Parameters
None.
Restrictions
None.
Example
To show SNMP engine ID:
552

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents