D-Link DGS-1510/ME Series Reference Manual page 609

Table of Contents

Advertisement

DGS-1510/ME Series Metro Ethernet Switch CLI Reference Guide
DGS-1510-28XMP/ME:admin# config time_zone operator + hour 2 min 30
Command: config time_zone operator + hour 2 min 30
Success.
DGS-1510-28XMP/ME:admin#
74-7
config dst
Description
This command is used to configure Daylight Saving Time of the device.
Format
config dst [disable | repeating {s_week <start_week 1-4,last> | s_day <start_weekday sun-sat> | s_mth
<start_mth 1-12> | s_time <start_time hh:mm> | e_week <end_week 1-4,last> | e_day <end_weekday sun-
sat> | e_mth <end_mth 1-12> | e_time <end_time hh:mm> | offset [30 | 60 | 90 | 120]} | annual {s_date
<start_date 1-31> | s_mth <start_mth 1-12> | s_time <start_time hh:mm> | e_date <end_date 1-31> | e_mth
<end_mth 1-12> | e_time <end_time hh:mm> | offset [30 | 60 | 90 | 120]}]
Parameters
disable - Specifies to disable the Daylight Saving Time of the Switch.
repeating - Specifies to set the Daylight Saving Time to repeating mode.
s_week - (Optional) Specifies to configure the start number of Daylight Saving Time.
<start_week 1-4, last> - Enter the starting week number of Daylight Saving Time here. This value must be
between 1 and 4.
s_day - (Optional) Specifies to configure the start day number of Daylight Saving Time.
<start_weekday sun-sat> - Enter the starting day value of Daylight Saving Time here. This value must
either be sun, mon, tue, wed, thu, fri or sat.
s_mth, e_mt - (Optional) Specifies to configure the start month number of Daylight Saving Time.
<start_mth 1-12> - Enter the starting month number of Daylight Saving Time here. This value must be
between 1 and 12.
s_time - (Optional) Specifies to configure the start time of Daylight Saving Time.
<start_time hh:mm> - Enter the starting time of Daylight Saving Time here. This value must be in the
hh:mm format.
e_week - (Optional) Specifies to configure the end week number of Daylight Saving Time.
<end_week 1-4, last> - Enter the ending week number of Daylight Saving Time here. This value must be
between 1 and 4.
e_day - (Optional) Specifies to configure the end day number of Daylight Saving Time.
<end_weekday sun-sat> - Enter the ending day value of Daylight Saving Time here. This value must
either be sun, mon, tue, wed, thu, fri or sat.
e_mth - (Optional) Specifies to configure the end month number of Daylight Saving Time.
<end_mth 1-12> - Enter the ending month number of Daylight Saving Time here. This value must be
between 1 and 12.
e_time - (Optional) Specifies to configure the end time of Daylight Saving Time.
<end_time hh:mm> - Enter the starting time of Daylight Saving Time here. This value must be in the
hh:mm format.
offset - (Optional) Specifies the number of minutes to add or to subtract during summertime. The ranges of
offset are 30, 60, 90,120. The default value is 60.
30 - Specifies that the offset range will 30 minutes.
60 - Specifies that the offset range will 60 minutes.
605