Datalogic Magellan 9800i Product Reference Manual page 93

Datalogic magellan 9800i sacnner
Hide thumbs Also See for Magellan 9800i:
Table of Contents

Advertisement

Shift Test (6 Pounds Dual Interval ONLY)
The Shift Test checks to ensure that items placed anywhere on the weighing surface of the
Figure 53. Shift Test
Product Reference Guide
scanner/scale are weighed properly. Refer to
Figure 53
1. Place and remove, in succession, a six-pound
load on the center of each of the four quadrants:
1, 2, 3, and 4, (as shown in
scanner/scale's weigh platter. Verify that a read-
ing of between 5.995 and 6.005 lb. registers,
under load, in each quadrant tested. Check that
the display returns to 0.00 between each load.
2. After verifying the accuracy of each quadrant of
the weighing surface, remove all weight from
the scale. This completes the 6 pound Shift Test.
(Models vary)
when performing this test.
DUAL INTERVAL
Figure
53) of the
1
2
4
3
81