Micro PDF 417 Length 1, Length 2 Programming Instructions

If Micro PDF 417 Length Control is set to Fixed-Length decoding, this feature specifies Micro
PDF 417 first fixed length. If Micro PDF 417 Length Control is set to Variable-Length
decoding, this feature specifies the minimum label length.
To set this feature:
1. Scan the ENTER/EXIT Programming Mode bar code.
2. Scan the barcode,
You'll need to cover any unused barcodes on this and the facing page to ensure that the
scanner reads only the bar code you intend to scan.
3. Scan the appropriate digits from the
label length. The selectable range for this option is 0001 to 0366. Pad all numbers with
leading zeros to yield a four-digit entry (0001-0366).
4. Complete the programming sequence by scanning the ENTER/EXIT Programming
Mode bar code.
Default setting for this feature = 0001
0351(CR)
Set Micro PDF 417 Length 2
Product Reference Guide
This tag is only valid for units with a model ID that supports PDF.
Length 1 is the minimum label length if in variable length mode, or
the first fixed length if in fixed length mode. Length 2 is the maxi-
mum label length if in variable length mode, or the second fixed
NOTE
length if in fixed length mode. Length includes the barcode's data
characters only. Any value > 0366 will be considered to be 0366.
Set Micro PDF 417 Length 1
Enter/Exit Programming Mode
Set Micro PDF 417 Length 2
or
Keypad
Appendix C
in
that represent the desired
0350(CR)
Set Micro PDF 417 Length 1
Default setting for this feature = 0366
below.