Calibration Procedures
Increasing- Load Test (Single Interval Phase 2)
(Dual Interval Phase 3)
The upper limit of the scale is configurable according to POS interface type and may not necessarily
be set at 15 kilograms, which is the standard setting. For this test, continue to place weights in 2.50
kilograms increments only to the upper weight limit set for your scale.
NOTE
SINGLE INTERVAL
After completing the Shift Test, you must complete
the Increasing Load Test using 10.00, 12.50 and
15 kilograms of weight.
1. Place 10.00 kilograms in the center of the
weighing surface and check that the display
reads between 9.990 kg and 10.010 kg.
2. Place an additional 2.50 kilograms in the center
of the weighing surface and check that the dis-
play reads between 12.490 kg and 12.510 kg.
3. Place an additional 2.50 kilograms in the center
of the weighing surface and check that the dis-
play reads between 14.990 kg and 15.010 kg.
4. Remove the weights and verify that the display
reads 0.000 kg.
5. You have completed Phase 2 of the increasing
load test.
Blanking Test
This test ensures that the scanner/scale will indicate its weighing capability has been exceeded
if a weight greater than 0.82 kilograms over its maximum upper weight limit is placed
upon the scale platter.
1. Place weights that total the upper limit plus 0.82 kilograms on the weigh platter. For
2. Verify that the display shows a dash and three hyphens (_---). This is the overweight 
The scanner/scale may blank (show an underscore and three hyphens) at any weight greater than its
upper limit plus 0.82 kilograms are set upon the weighing surface.
NOTE
88
example: If the upper limit is set at 15 kilograms, place weight totaling 15.82 kilo-
grams.
indication.
DUAL INTERVAL
After completing the Shift Test, you must complete
the Increasing Load Test using 10.00, 12.50 and
15 kilograms of weight.
1. Place 10.00 kilograms in the center of the
weighing surface and check that the Remote 
Display reads between 9.990 kg and 10.010 kg.
2.
Place an additional 2.50 kilograms in the center of
the weighing surface and check that the display
reads between 12.490 kg and 12.510 kg.
3.
Place an additional 2.50 kilograms in the center of
the weighing surface and check that the display
reads between 14.990 kg and 15.010 kg.
4.
Remove the weights and verify that the display
reads 0.000 kg.
5. You have completed Phase 3 of the Increasing
Load Test.