CAUTION
NOTE
3. The unit should be permitted to reach thermal equilibrium before proceeding to the next
4. Verify that the scanner or scanning-scale passes an operational test by observing the fol-
Scanner — Pass UPC/EAN bar code labels in front of the scanner's windows. Since the interface
NOTE
EAS System — The way in which EAS tags are deactivated is dependent upon the way the scan-
Product Reference Guide
Additionally, the Health & Status Indicator will flash the number '9', indicating the EAS
system is being initialized.
If the Selftest detects a problem, the Health & Status Indicator will display a num-
ber code. Refer to
codes and problem isolation procedures.
On rare occasions, performance of scale calibration may be necessary to obtain a
zero reading on the display.
steps. (Reference the topic
a cooler temperature (such as a storage area) to a warmer environment (such as a check-
stand location), a period of 60 minutes must be allowed to acclimate the unit to ambient
conditions. Once installed and powered up, a "power-up" warm-up period of 15 minutes
must be allowed before calibrating or performing weighing operations. These two warm-
up periods may run concurrently.
lowing:
cable is not yet connected to the POS terminal, the scanner may be limited to reading
only one or two labels (see the note that follows). The scanner indicates when each label
has been successfully read by flashing the green scanner light and emitting a good read
tone (beep).
When not connected to the host, the scanner may be limited to reading only one
or two labels. (This limitation is dependent upon the interface type.) To scan mul-
tiple labels without connecting to the host, place the unit in Scanner Diagnostic
Mode by pressing the Scanner Control Button for four seconds.
ner is currently programmed with regard to EAS Mode. (See "EAS Mode" on page 42.) To
test EAS system function...
Coupled Mode — Pass an item containing both a bar code and an active EAS tag over the
scanner. Successful deactivation is indicated by the bottom-most LED flashing first red,
then orange, then returning to green. The beeper will sound a good read beep.
If you have enabled the manual deactivation function available for Coupled Mode (see
"Manual EAS Deactivation Push Button" on page -48), test the function by pressing the
bottom push button. A ticking sound will be heard which should cease upon deactivating
an EAS tag.
Decoupled Mode — In this mode, items do not require a bar code to be scanned to arm
the deactivation function. Simply pass an active EAS tag over the scanner in the same
direction you would scan a bar code. The bottom-most LED will flash red to indicate
deactivation. No beep is sounded to indicate deactivation in this mode.