Funkwerk Bintec R41000 Reference page 281

Bintec r1xxx/r3xxx/r4xxx gateways reference manual
Table of Contents

Advertisement

Funkwerk Enterprise Communications GmbH
R1xxx/R3xxx/R4xxx
Fields in the Advanced Settings menu
Field
Block after connection
failure for
Maximum Number of
Dialup Retries
Usage Type
Authentication
Description
Enter the wait time in seconds before the device should try
again after an attempt to set up a connection has failed.
The default value is
.
Enter the number of unsuccessful attempts to setup a connec-
tion before the interface is blocked.
Possible values are
to
The default value is .
If necessary, select a special interface use.
Possible values:
(default value): No special type is selected.
: The interface is used for incoming dialup
connections and callbacks initiated externally.
multi-user connection partner, i.e. several clients dial in with
the same user name and password.
Select the authentication protocol for this PPTP partner.
Possible values:
(default value): Only run PAP (PPP Password Authentic-
ation Protocol); the password is transferred unencrypted.
: Only run CHAP (PPP Challenge Handshake Authentic-
ation Protocol as per RFC 1994); the password is transferred
encrypted.
: Primarily run CHAP, otherwise PAP.
: Only run MS-CHAP version 1 (PPP Microsoft
Challenge Handshake Authentication Protocol).
: Primarily run CHAP, on denial then the
authentication protocol required by the connection partner.
(MSCHAP version 1 or 2 possible.)
: Run MS-CHAP version 2 only.
: Some providers use no authentication. In this case, se-
.
: The interface is defined as
17 WAN
255