11 Physical Interfaces
132
Field
ISDN Line Framing
P-P Base Number
Channel Selection
Funkwerk Enterprise Communications GmbH
Description
: You can select a leased line.
: EQ-SIG S2M User Profile
: Q-SIG S2M Network Profile
Only if Port Usage is selected.
Select the framing type for layer 1.
Possible values:
(default value)
The default value can be left in the majority of scenarios. You
can use the
option if required (e.g. in Sweden and
France), if the device is to be connected to a PABX.
Only if Port Usage is not
.
.
Enter the basic number of the connection.
With incoming calls, this basic number is removed from the
called number (Called Party Number).
With outgoing calls, this basic number is attached to the call
number to be called (Calling Party Number).
Only if Port Usage =
,
An additional option is provided in order to guarantee the com-
patibility with special providers: If you set the switch type appro-
priately, you can select a value for the variable Channel Selec-
tion. This defines how the B channel is selected for an outgoing
call.
Possible values:
(default value): The device tells the PABX that
all channels are available. The exchange of the PABX selects
the channel to be used.
,
,
or
.
R1xxx/R3xxx/R4xxx
or

Advertisement