Previous view
8
D-STAR OPERATION <BASIC>
"FROM" (Access repeater) setting (Continued)
D Using the DR mode scan
The DR mode scan is useful to find a repeater.
To quickly find a repeater, the DR mode scan skips re-
peaters that are not specified as an access repeater.
(The "USE (FROM)" setting is set to "NO" (SKIP is set)
on the repeater list.)
Example: Select the "Hirano" repeater using the DR
mode scan.
Push
(C) to select the DR mode.
q
DR
Push
(C) to display the "D-1" screen (D-1
w
MENU
menu).
Touch [SCAN](
D) to start the DR mode scan.
e
• The frequency decimal point and "FROM" blink while
scanning.
• The repeaters in the repeater list are sequentially dis-
played.
• The scan pauses when a signal is received. The scan
resumes the same as other scans. (p. 12-5)
When the transceiver receives a signal from a re-
r
peater, the scan stops, then touch [SCAN](D) .
• The DR mode scan is cancelled.
You can skip certain repeaters as a scan target. You
can also skip all repeaters in certain groups from a
scan. See page 9-42 for details.
NOTE:
Even if the transceiver receives a signal from a re-
peater, the repeater may not receive the transceiv-
er's signal, because the repeater's output power is
higher than the transceiver's.
The DR mode scan also scans simplex frequencies if
they are entered in the repeater list.
Blinks
While receiving a
signal on 438.030.
L eft
D isplay
C enter
Blinks
While DR mode scanning
While receiving a signal
from a repeater
"Hirano" repeater is selected in
"FROM."
8-10
The L, R, C or D in the
R ight
instructions indicate the
part of the controller.
L: Left side
R: Right side
C: Center bottom
D: Display (Touch screen)
Touch [SCAN]
The repeaters
are sequentially
displayed.
Means "JM1ZLK"
is using the "Hi-
rano" repeater.
Touch [SCAN]
Need help?
Do you have a question about the IC-7100 and is the answer not in the manual?
Questions and answers
IC-7100 is two months old. Power suddenly cut off. Fuses are OK. No obvious damage internally. Can something with the control head cause unit not to power up?
Yes, a control head issue can cause the Icom IC-7100 to not power up. The control head receives power through the extension cable with shielded RJ45 connectors. If there is high resistance in the power wires or a poor connection in the umbilical cable, it may prevent the control head from receiving enough power to function properly. Reseating both connectors may help resolve the issue.
This answer is automatically generated