D Sing The Preloaded Repeater List - Icom IC-7100 Advanced Instructions

Hf/vhf/uhf all mode transceiver
Hide thumbs Also See for IC-7100:
Table of Contents

Advertisement

Previous view
8
D-STAR OPERATION <BASIC>
"FROM" (Access repeater) setting (Continued)
D Using the preloaded repeater list
When your access repeater is preloaded in your trans-
ceiver's repeater list, you can select it from the repeater
list.
By only selecting the repeater from the list, the call
sign, frequency, duplex and offset frequency settings
are automatically set for easy operation.
Example: Select the "Hirano" repeater in Japan from
the repeater list.
Push
(C) to select the DR mode.
q
DR
Check whether or not "FROM" is selected.
w
• If "FROM" is not selected, touch the "FROM" field.
Touch the "FROM" field.
e
• The "FROM SELECT" screen appears.
Touch "Repeater List."
r
• The "REPEATER GROUP" screen appears.
Touch the repeater group where your access repeat-
t
er is listed. (Example: "11: Japan")
Touch your access repeater to select the repeater
y
area or name. (Example: "Hirano")
• The transceiver returns to the DR mode screen, and the
selected repeater is set in "FROM."
L eft
D isplay
R ight
C enter
How to switch the repeater group:
To switch the repeater group, while in the DR mode,
push
(C), and then touch "Group Select"
QUICK
The repeater list, described in this manual, may dif-
fer from your transceiver's preloaded list.
The L, R, C or D in the
instructions indicate the
part of the controller.
L: Left side
R: Right side
C: Center bottom
D: Display (Touch screen)
"FROM" is selected.
Repeater area
(Sub name)
"Hirano" is set on "FROM."
8-9
Touch
"FROM."
Touch
"Repeater List."
Touch the re-
peater group
( Example:
"11: Japan")
Touch your ac-
cess repeater.
( Example:
"Hirano")
Repeater call sign

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IC-7100 and is the answer not in the manual?

Questions and answers

William Carpenter
January 26, 2025

IC-7100 is two months old. Power suddenly cut off. Fuses are OK. No obvious damage internally. Can something with the control head cause unit not to power up?

1 comments:
Mr. Anderson
February 10, 2025

Yes, a control head issue can cause the Icom IC-7100 to not power up. The control head receives power through the extension cable with shielded RJ45 connectors. If there is high resistance in the power wires or a poor connection in the umbilical cable, it may prevent the control head from receiving enough power to function properly. Reseating both connectors may help resolve the issue.

This answer is automatically generated

Norman Dorn
May 3, 2025

re ICOM 7100. Digital mode operations leave the mike path inoperable. What protocols are required on the DV USB computer/transceiver cable? Transceiver control head display shows USB-D when the intent is USB.

Table of Contents

Save PDF