EPSON EPL-N3000/AcuLaser M4000N
3.3.6 Full Stack Error/500 Paper Exit
Table 3-58. Troubleshooting for "Full Stack Error/500 Paper Exit"
Step
Action and Question
Parts below can be the source of this error
• SENSOR FULL STACK
(p.268)
• ACTUATOR FULL STACK
• HVPS/MCU
(p.301)
ACTUATOR FULL STACK
1
♦
Does the ACTUATOR FULL STACK in the paper
exit operate smoothly?
SENSOR FULL STACK
2
1.
Replace the SENSOR FULL STACK.
♦
After the SENSOR FULL STACK is replaced, does
the problem still occur?
Troubleshooting
Yes
(Chapter 4 Disassembly and
Assembly)
(p.269)
Replace the
ACTUATOR
Go to Step 2
FULL
STACK
(p.268).
Replace the
Problem
HVPS/MCU
solved
Troubleshooting for Faulty Operation
No
Revision C
109
Confidential