Epson EPL-N3000 Service Manual page 105

A4 monochrome laser printer
Hide thumbs Also See for EPL-N3000:
Table of Contents

Advertisement

EPSON EPL-N3000/AcuLaser M4000N
Table 3-53. Troubleshooting for "Power Does Not Turn ON" (continued)
Step
Action and Question
Fuse
1.
Remove the SHIELD PLATE LVPS. (p.285)
3
2. Check to see if the fuse on the LVPS is blown.
Is the fuse blown?
550 Option Feeder
1.
Remove the 550 FEEDER OPTION. (p.311)
2. Check whether the two FANs operate or not
when power is switched on.
4
Do the two FANs operate?
Option Duplex
1.
Remove the Option Duplex. (p.342)
5
2. Check whether the two FANs operate or not
when power is switched on.
Do the two FANs operate?
24V Power Supply
1.
Remove the SHIELD PLATE HVPS. (p.296)
2. Make certain that P/J10 is connected to the
HVPS/MCU. (refer to
"Connectors
3. Remove the Imaging Cartridge.
6
4. Measure the voltage across each of the following
pairs:
P/J10-1 ↔ P/J10-4
P/J10-2 ↔ P/J10-5
P/J10-3 ↔ P/J10-6
P/J10-8 ↔ P/J10-7
Is each voltage 24 VDC?
Troubleshooting
Yes
No
Replace the LVPS Go to Step 4
Go to
3.4.21 PWBA
FEEDER 550
(p.130),
3.4.22 PWBA
FEEDER 550
Go to Step 5
(p.130),
3.4.26 CLUTCH
ASSY PH (p.134)
and
3.4.27 CLUTCH
PR-REGI (p.135)
Go to
3.4.28 PWBA
DUPLEX (p.136)
Go to Step 6
and
3.4.29 MOTOR
DUPLEX (p.136)
(p.406)")
Go to
Go to Step 7
LVPS
(p.111)
Troubleshooting for Faulty Operation
Table 3-53. Troubleshooting for "Power Does Not Turn ON" (continued)
Step
Action and Question
CLUTCH REGI
1.
Remove the SHIELD PLATE HVPS. (p.296)
2. Disconnect P/J243 from the HVPS/MCU.
7
3. Remove the Imaging Cartridge.
4. Check to see if the Fan Main operates at turning
power on.
Does the Fan Main operate?
OPERATION PANEL
1. Disconnect the HARNESS ASSY PANEL from
the Main Board.
2. Remove the Imaging Cartridge.
8
3. Turn on the main power.
4. Check for wind from the exhaust hole at the rear
of the printer to see if the Fan Main operates.
Does the Fan Main operate?
HARNESS ASSY PANEL
1. Disconnect the HARNESS ASSY PANEL from
the Main Board.
9
2. Check the harness for broken wire or short
circuit.
3. Check continuity of each wire of harness.
Is the harness free from broken wire or short
circuit and do all the wires have continuity?
ROS ASSY
1. Disconnect P/J13, P/J14, P/J16 and P/J17 from
3.4.1
the HVPS/MCU.
10
(Refer to
"Connectors
2. Remove the Imaging Cartridge.
3. Turn on power.
Does the Fan Main operate?
Yes
Go to
3.4.13
CLUTCH REGI
(p.123)
Go to Step 9
Replace the
OPERATION
PANEL
Replace the ROS
(p.406)")
ASSY
Revision C
No
Go to Step 8
Go to Step 10
Replace the
HARNESS
ASSY
PANEL
Go to Step 11
105