EPSON EPL-N3000/AcuLaser M4000N
4.3.7 HANDLE EXTENTION 150
Removal
1.
Remove the COVER CST from the cassette body.
2.
Remove the two screws located the backside of the HANDLE EXTENSION 150
3.
Release the five hooks at the top and two hooks at the bottom, and remove the
HANDLE EXTENSION 150 from the HOUSING EXTENSION 150.
Installation
1.
Fit the hooks of the HANDLE EXTENSION 150 (5 points at the top, 2 points at
the bottom) to the HOUSING EXTENSION 150.
2.
Secure the HANDLE EXTENSION 150 with the two screws.
3.
Install the COVER CST to the cassette body.
Disassembly and Assembly
HANDLE EXTENSION 150
Figure 4- 22. HANDLE EXTENTION 150 Removal
150 Paper Cassette
Revision C
JG3301AA
190