Functional Diagrams - Kodak DryView 5800 Service Manual

Laser imager
Hide thumbs Also See for DryView 5800:
Table of Contents

Advertisement

A
B
C
D
E
ANT SEL 0
+5 V
1
RF Tag
+5 V
Tranceiver
LED3
RF Tag
LED1
Happy
RF Tag
Upper R/W
RX In
J1
RF Tag
Data In
1
TX Out
Antenna
2
ANT SEL 1
Data Out
2
Upper
SCLK
RF Tag
+5 V
RCVR/
LED2
13.56
XMTR
XTAL 1
MHz
Error
RF Tag
Lower R/W
RF Tag
J2
3
Antenna
1
Lower
2
ANT SEL 0
3
ANT SEL 1
4
DRE
Defaults
Switch
S2
I 2 C Bus
J10
SCL
< >
13
SDA
5
14
< >
From
SOP
12
1
Datapath Board
2
(See Sheet 1)
+5 V
3
4
Laser 24 V
5
6
+12 V
Reset
7
+5 V
From Voltage
Switch
8
Regulators
S1
9
+3.3 V
6
10
11
I 2 C Bus
7
8
9
I 2 C Bus
10
Laser 24 V
Service Switch
(Shown in
11
User Position)
Interlock
Switches
12
AC Power for Drum Heaters
{
To Processor Control
Board Connector J3
13
14
24 V DC
Power Supply
15
Power
+24 V DC
1
AC Power In
Switch
80 - 240 Volts
2
Line
BLK
3
3
Neutral
WH
Common
2
4
Circuit
5
1
Breakers
6
15 Amp
16
A
B
C
D
E
2G0947 - 31JAN08
I
F
G
H
K
L
+5 V
J6
16 MHz
Drive Enable
1
OSC 1
Drive Direction
2
Reset
3
NU
4
NU
5
6
7
Reset
8
Clock
+5 V
Micro-
I 2 C Bus
Processor
+3.3 V
SCL
LED4
SDA
FPM
+5 V
Happy
Hazard 24 V
Master
Microprocessor
Serial Port Receive
Serial Port Transmit
+5 V
Microprocessor Reset Signals
16 MHz
Osc.
Select Upper Sensors
Select Lower Sensors
SENSOR INPUT
Select Misc
MUX
Enable
Sensors
Upper
<
Lower
Sensor Inputs
<
Misc.
<
< >
Laser
Interlock
Status
J19
Laser 24 V
Enable Sensors
NC
I 2 C Bus
4
3
+24 V
2
1
NO
+3.3 V
Laser
J16
Interlock
Door
Top
1
Interlock
Cover
2
LED13
J17
LED16
Left
1
2
Panel
Laser 24 V
J18
1
Right
2
Panel
+24 V
Hazard 24 V
Door
Test Points
Interlock
Relay
Hazard 24 V
GND1
1
1
+5 V
2
2
GND2
1
+24 V
1
2
2
GND3
+12 V
1
1
2
Door Interlock - +5 V
2
GND4
+5 V
1
1
2
2
1
+3.3 V
2
Circuit
+24 V
+3.3 V
+5 V
Breaker
J20
15 Amp
4
+24 V DC
3
2
5 V Voltage
12 V Voltage
1
3.3 V Voltage
Regulator
Regulator
Regulator
Voltage Regulators
F
G
H
J
K
L
M
N
P
Q
R
S
Exposure Transport
>
Motor and Circuit Board
(Part of Imaging Assembly)
1
NU
2
3
M7
4
3
2
1
Film Path Micro (FPM) Board
Motor Enable Lines
Slave
(Motor Control)
Microprocessors
Stepper Motor
Drivers
<
Upper
<
4
Pickup Drive
Motor Control
Lower
4
Upper
4
Film Tray
Unlock Motor
Control
Lower
4
Film Feed Roller
Drive Motor Control
4
Turnaround(Kick)
Roller Motor
4
Control
Processor Drum
Drive Motor
4
Control
Feed Roller NIP
Open/Close Motor
4
Control
<
< <
<
Hazard 24 V
(Motor Power)
Door interlock
Status
Door Interlock - +5 V
(Driver Logic Power)
+3.3 V
NOTE: See Sheet 2 for LED descriptions
+5 V
J9
I 2 C Bus
1
2
3
4
Hazard 24 V
5
6
J8
1
2
Local Panel
3
4
J7
1
SDA
2
To Densitometer
SCL
3
(See Sheet 1)
+12 V
4
J11
+12 V
+12 V DC Power to DRE
1
{
2
(See Sheet 1)
3
4
NU
5
6
J21
+24 V
1
Processor
2
Fan
M
N
P
Q
R
S

Functional Diagrams

Kodak DryView 5800 LASER IMAGER - System Functional Block / Wiring Diagram - Sheet 3 of 4
2008 January Rev. A 2G0849
T
U
V
W
X
Wiring Harness
(Motor Power)
Hazard 24V
J13
See sheet 4 for details
RED
1
Motor Drivers
BLK
2
WHT
5
Vacuum
RED
6
Pump
YEL
11
ORN
12
RED
13
BRN
14
Vacuum Valve
YEL
7
ORN
Upper
4
8
RED
9
BRN
10
RED
3
BLK
4
Separation
4
Fans
J5
RED
4
GRN
2
BLK
6
RED
13
Vacuum Valve
GRN
11
Sensor
BLK
Lower
9
Power
RED
16
+ 5 V
GRN
14
<
BLK
12
RED
22
GRN
20
BLK
18
RED
19
GRN
23
BLK
21
RED
1
GRN
5
BLK
3
Pins 7,8, 10,
15, 17 and
24-30 NU
Power and Ground
To All Film Supply
Sensors
J12
WHT
4
RED
5
YEL
10
ORN
11
4
RED
12
BRN
13
YEL
6
ORN
7
4
RED
8
BRN
9
{
1
NU
2
3
J4
RED
4
GRN
2
BLK
6
RED
13
GRN
11
BLK
9
RED
<
16
GRN
14
BLK
Sensor Inputs
12
RED
19
GRN
23
BLK
21
RED
1
GRN
5
Film Supply Sensor LEDs
BLK
See sheet 2
3
Pins 7,8, 10,
+5 V
15, 17, 18, 20,
22 and 24-32 NU
J14
+5 V
YEL
1
ORN
2
4
RED
3
BRN
4
BRN
5
RED
6
4
ORN
7
YEL
8
BRN
9
RED
10
4
ORN
11
Enable Film
YEL
12
Supply Sensors
J15
{
1
Switch
1
NU
2
JP2
2
YEL
3
Install Jumper on
Ground Enables
4
ORN
4
JP2 to override
RED
Sensors
5
BRN
sensor control
6
Processor Control
High = 88 - 140 V AC (set heaters in parallel)
AC Voltage
<
Sense Circuits
Board (PCB)
Low = 173 - 264 V AC (set heaters in series)
+24 V TEST
Hazard +24 V
D4
Interlock
+5V
K1
ON
+5 V
Vcc
Enable AC Line Voltage
Happy
J1
1
D5
Vcc
2
3
Hazard +24 V
Solid State
4
D6
5
(SSR)
Relay
6
SSR
IN +
LOAD
Micro
7
8
I 2 C
Controller
IN -
LOAD
SCL
Heaters
9
< >
10
SDA
< >
ON/OFF
Reset
Circuit
Reset
Switch
Heater configuration:
Low = Heaters in series
High = Heaters in parallel
A to D
RTD Sense Circuits
<
Converter
T
U
V
W
X
Y
Z
AA
1
M4
Vacuum
2
Pump
1
1
Vacuum
M5U
3
Valve - Upper
- 6
- 4
Pickup Drive
- 3
M3U
Motor - Upper
- 1
6
Film Tray
4
M6U
3
Unlock Motor
2
1
Upper
Upper Film
1
2
Separation
3
Fan
Lower Film
1
Separation
2
Fan
3
S1U
+5 V
Sensor Power
1
Pickup Home
{
Output (LOW =
2
Sensor Blocked)
Sensor - Upper
3
Ground
S2U
1
2
Film Contact
3
Sensor - Upper
4
1
S3U
2
Film Separated
3
Sensor - Upper
1
S4
2
NIP Roller Position
3
Sensor
1
S5U
2
Cassette-In
5
3
Sensor - Upper
1
S6U
2
Film Saver
3
Sensor - Upper
1
Vacuum
M5L
3
Valve - Lower
6
6
4
Pickup drive
M3L
3
Motor - Lower
1
6
4
M6L
Film Tray
3
Unlock Motor
1
Lower
7
+5 V
Sensor Power
S1L
1
{
Output (LOW =
Pickup Home
2
Sensor Blocked)
3
Sensor - Lower
Ground
S2L
1
8
2
Film Contact
Sensor - Lower
3
1
S3L
2
Film Separated
3
Sensor - Lower
S5L
1
2
Cassette-In
3
Sensor - Lower
9
S6L
1
2
Film Saver
3
Sensor - Lower
6
Film Feed Roller
4
M1
NIP Open/Close
3
Motor
1
1
10
Turnaround (Kick)
3
M9
Roller Drive
4
Motor
6
1
3
Processor Drum
M8
4
Drive Motor
6
11
6
4
Film Feed Roller
M2
3
Drive Motor
1
100 - 240 V AC
Power for Drum
Heater
12
(From Power
Switch)
Line
J3
1
2
3
4
5
13
6
Neutral
Slip
14
Rings
J4
3
5
4
Drum
6
10
Heater
5
2
1
3
+5 V
2
K2
4
15
7
D2
8
9
Heater
Config
(ON = Parallel)
1
Drum
RTD
6
16
Y
Z
AA
7-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents