PROCESSOR CONTROL BOARD (PCB)

D5
S1
J6
JP3
JP1
JP2
Item
D2
CONFIG LED - When lit, the AC line voltage is 88 - 140 V AC (the 2 DRUM HEATERS are
connected in parallel). When unlit, the voltage is 173 - 264 V AC (the 2 DRUM HEATERS are
connected in series).
D4
INTLK LED - When lit, the MICROCONTROLLER has enabled the line voltage to the DRUM
HEATER. This LED will be OFF briefly at times, but during normal operations is continuously
lit.
D5
"Happy" LED - When the MICROCONTROLLER is functioning normally, this LED blinks
slightly faster than once a second. During MICROCONTROLLER reflash, the LED may freeze
momentarily. If the LED is steady ON or steady OFF, the MICROCONTROLLER is not
functioning.
D6
SSR LED - This LED pulses ON and OFF in 2 second cycles as the Solid State Relay (SSR)
switches HEATER power ON and OFF.
JP1
Test point for +3.3 V.
JP2
Test point for +2.5 V.
JP3
Test point for Ground.
+24VTEST
Test Point for Hazard 24 V.
LINE,
Test points for AC line voltage at the input of the PCB.
NEUTRAL
S1
RESET SWITCH - Pressing this SWITCH causes a Checksum and Memory test to run for the
software on the PCB.
2G0947 - 31JAN08
J1
D2
D4
D6
+24VTEST
PCB
Table 5-8: PCB LEDs and Test Points