Diagnostics
Condition Code: 25-922
Web Portal Message
RF Tag: Internal Diagnostic
Failure
Condition Code: 25-931
Web Portal Message
RF Tag: Internal
Communications Failure
5-78
Log Message
RF Tag reader failed self
diagnostics
Description
When the RF Tag reader is told to perform diagnostics and returns a diagnostics
failure, the Machine Control System (MCS) commands a retry. This error is
indicated if the MICROCONTROLLER still indicates a diagnostics failure after
3 attempts. The error clears only when power is cycled.
System Impact
The printer is unable to print films. The spooler is still able to accept and queue
jobs but new films will not be initiated. Films downstream of the affected
subsystem will be completed. All other films will be reprinted.
User Action
1. Shut down the IMAGER, then start the IMAGER.
2. If the error persists, call for service.
FE Action
Log Message
MCS failed to communicate
with RF Tag micro after
multiple attempts
Description
This error occurs when the Machine Control System (MCS) tries to
communicate with the MICROCONTROLLER but receives no response to 5
attempts. The error clears only when power is cycled.
System Impact
The printer is unable to print films. The spooler is still able to accept and queue
jobs but new films will not be initiated. Films downstream of the affected
subsystem will be completed. All other films will be reprinted.
User Action
1. Shut down the IMAGER, then start the IMAGER.
2. If the error persists, call for service.
FE Action
DICOM Message
BAD SUPPLY MGZ
0-Fatal
DICOM Message
ELEC DOWN
0-Fatal
2G0947 - 31JAN08
Severity
Severity