2G0947 - 31JAN08
13. Remove:
HEAT SHIELD
2 SCREWS
FELT PAD AY
FILM DIVERTER AY
14. Discard the FELT PAD AY.
CAUTION
:
ISOPROPYL ALCOHOL is highly flammable. Follow the
manufacturer's instructions for safe use and handling.
15. Use ALCOHOL WIPES and SCRAPER to inspect and clean the
following components:
HEAT SHIELD
FILM DIVERTER AY
SIDEPLATES
COOLING PLATE
FILM DIVERTER MOUNTING BRACKET
16. Inspect and clean the PROCESSOR DRUM while it is still mounted in
the PROCESSOR AY.
NOTE:
Wipe the PROCESSOR DRUM with ALCOHOL WIPES in one
direction with an even steady pressure. Rotate the PROCESSOR
Drum while wiping.
Check the PROCESSOR DRUM for imperfections, gouges and
excessive buildup areas of debris.
17. Remove the PROCESSOR DRUM (see Adjustments And Replacements,
"PROCESSOR DRUM" on page
18. Clean the PROCESSOR DRUM in an upright position on a flat stable
surface.
Preventive Maintenance
3-27).
4-7