Mxe Iii (Single Hard Disk Or Solid State Drive) - Mitel 3300 Technician's Handbook

3300 ip communications platform communications director release 5.0
Table of Contents

Advertisement

3300 ICP Technician's Handbook
15. To copy data onto the second new hard drive, complete steps 11 to 13
of the "Replace One Hard Drive in an MXe II/MXe Server" procedure
on page 210.
16. To reinstall and/or relicense the software, follow the steps in "Recover
MXe Server" on page 146.

MXe III (Single Hard Disk or Solid State Drive)

The MXe III ships from the factory without a storage media. Use the
following procedure to install or replace one of the following:
• 160 GB SATA hard drive
• 32 GB SATA solid state drive (SSD)
The flash drive includes MCD software and installs exactly the same way
as a single hard drive
Note: To install two hard drives for RAID functionality, see "MXe III (Two
Hard Drives)" on page 215. RAID is not available for solid state drives.
To replace the single hard drive or SSD in an MXe III controller:
1. For first-time installation skip to Step 2. To replace the drive,
-
If possible, back up your database (or locate the most recent
backup).
-
loosen the captive screw and slide the defective hard (HD1) drive
from the drive carrier.
-
remove the four screws that secure the drive to the carrier.
Slide the (replacement) hard drive or SSD into the drive carrier and
secure with the four screws. Ensure the hard drive is oriented as
illustrated in Figure 75.
Figure 75: Hard Drive / SSD Installed in Drive Carrier
2. Push to seat the hard drive or SSD into the backplane.