3300 ICP Technician's Handbook
Table 73: MXe III RAID Link LEDs (continued)
Hard Drive
State
Failure
Mismatch
FIM
The top LED indicates the status of local FIM. The bottom LED indicates
the status of the remote FIM.
The controller FIM monitors the synchronization of the clock appearing on
the fiber link from the peripheral cabinet or DSU. The FIM in the peripheral
cabinet or DSU monitors the synchronization of the clock appearing on the
fiber link from the controller.
LED Status
Meaning (Both LEDs)
ON
In-frame synchronization.
Flashing
Out of synchronization OR Tx and Rx fiber optic cables
reversed.
OFF
Power off OR held in reset.
340
HD 1
HD 2
BLUE
Slow BLUE
flashing
Slow BLUE
BLUE
flashing
BLUE
BLUE flashing
SOS signal
(Three quick flashes
followed by three slow
flashes)
BLUE flashing
BLUE
SOS signal
Table 74: Controller FIM LEDs (LX)
Description
HD 2 failed or out of
date
HD 1 failed or out of
date
HD 2 was swapped but
does not match
HD 1 was swapped but
does not match
Page 2 of 2