3300 ICP Technician's Handbook
Figure 67: APC-CX(i) II Hard Disk Drive Removal
5. Place the faulty hard disk drive into an anti-static bag.
6. Remove the replacement APC-CX(i) II hard disk drive from its
anti-static bag.
7. Install and secure the replacement hard disk drive in the orientation as
shown in Figure 67 (page 200).
8. Reconnect the cables.
9. Replace the cover.
10. Reinstall the MSL software. See "Installing MSL Software on APC
(CX/CXi) or APC-CX(i) II (CX II/CXi II)" on page 105 of this document.
To replace the APC-CX(i) II Battery:
CAUTION: Replace the APC-CX(i) II battery with a Panasonic
CR2032 battery only. Do not dispose of batteries in a fire as
they may explode. Batteries may also explode if damaged. Dis-
pose of batteries according to local regulations. Please recy-
cle when possible.
1. Power down the controller and remove the controller cover; see pages
47 and 129.
2. Remove the dead battery from the coin cell holder. The battery is
located on the APC-CX(i) II assembly next to the housekeeping cable
connector. To remove the battery:
200