Collecting System Logs Manually - Mitel 3300 Technician's Handbook

3300 ip communications platform communications director release 5.0
Table of Contents

Advertisement

Older Hardware and Software
FIM circuit 1 must always be connected, as it provides the master clock for
the other circuits. Identify circuit 1 as a peripheral cabinet in ESM.
Optionally, connect FIM Circuits 2 and 3 as DSU pairs in the cabinet,
identifying them as NSU pairs in ESM.
Any DSU or peripheral cabinets that were previously connected to the
MicroLIGHT must now be connected by fiber directly to the 3300 ICP
controller.
Figure 166: SX-2000 MicroLIGHT under 3300 control

Collecting System Logs Manually

Collecting System Logs - Release 5.1 System
To collect the logs on a Release 5.1 system:
1. Log into the System Administration Tool (see page 71).
2. Select System Diagnostics and then click Export.
3. Click Export and then click Continue.
4. After the File Download dialog box appears, click Save.
5. Navigate to a folder or network drive on your PC. Ensure that the file
extension is set to (.tar).
6. Click Save and then click Close.
405

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents