Mitel 3300 Technician's Handbook page 26

3300 ip communications platform communications director release 5.0
Table of Contents

Advertisement

3300 ICP Technician's Handbook
Connect Laptop PC
1. Power up the MXe Server and wait approximately 3 minutes for the
software to enable the printer port.
2. Connect the RS-232 serial cable between the COM 1 port on your
laptop to the server printer port (see Figure 1).
3. Open a communication application (for example ProCom or
Hyperterminal) on your laptop to the 3300 ICP and set the connection
parameters as follows:
Table 2: Communication Connection Parameters
Parameter
Port
Bits Per Second
Data Bits
Parity
Stop Bits
Flow Control
Emulation
16
Figure 1: Laptop Connections
Required Setting
COM 1 (example only)
38400
8
None
1
None
VT100

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents