Mitel 3300 Technician's Handbook page 235

3300 ip communications platform communications director release 5.0
Table of Contents

Advertisement

Figure 80: Routing the Pre-formed IDE Interconnect Cable
12. Carefully lower the MXe carrier chassis back into place. Ensure that
the ribbon cable is in the channel and does not become pinched
between the cabinet frame and the MXe carrier chassis.
13. Slide the MXe carrier chassis back into position. Ensure that the
metalwork beneath the faceplate engages the cabinet chassis.
Tighten the chassis retaining screw (see Figure 34 for the location of
the chassis retaining screw).
14. Reconnect the power cables to the connectors on the MXe carrier
chassis. Then, connect power connector to RAID controller.
15. Reinstall the Stratum 3 clock module with the retained screws (MXe II
only).
16. If an AMB is present, reconnect the power and ribbon cables between
the AMB and the MXe carrier board.
CAUTION: DO NOT install second hard drive.The hard drives
in a redundant hard drive system must have the same size
(accessible capacity).
17. Replace the top cover and secure with screw.
18. Power on controller and proceed with step 7 of section "Replace One
Hard Drive in an MXe II/MXe Server" on page 210.
Install and Replace Units
(SUPPLIED WITH 2-PACK
HARD DRIVE KIT)
225