Table 81: Controller T1/E1 Combo Card
Status LED
(green)
Off
Off
Off
Solid Green
Solid Green
Flashing Green
Flashing Green
Quad BRI Framer Module
For each BRI port on the Quad BRI MMC, there are two LEDs - red on the
upper left and green on the upper right. These LEDs represent the status
of the BRI ports as described in Table 82.
Figure 153: Controller BRI Framer LEDs
Alarm LED
(red/yellow)
Off
Solid Red
Solid Yellow
Solid Yellow
Off
Solid Yellow
Flashing Red
Meaning
Link not programmed or link descriptor
not assigned.
Red alarm. Loss of signal; check link
connection.
Yellow alarm. No signal from remote end;
check link with analyzer. (This state is
normal during startup.)
Blue alarm. Check link with analyzer.
Layer 1 synchronized. Good link state; no
alarms.
Alarm indication from remote end.
The card is in resilient mode.
Status LEDs
347