3. Tighten the captive screw.
4. Manually install the software on the hard drive or SSD (see "Install
System Software Manually" on page 85).
5. Reconnect the controller to the network.
6. If you backed up your database in Step 1, restore the database (see
"Restore a Database" on page 132).

MXe III (Two Hard Drives)

If the MXe III has two hard drives in a RAID (Redundant Array of
Independent Disks) configuration, you can replace one or both of them.
Note: If the system is under warranty, you must replace both hard drives.
Before proceeding with a warranty claim, contact Mitel Repair Services
(page 9) to obtain a Return of Merchandise Authorization (RMA) number.
"Replace One Hard Drive in an MXe III" on page 215
"Replace Both Hard Drives in an MXe III" on page 216
Replace One Hard Drive in an MXe III
Replace one hard drive in a RAID configuration if only one hard drive is
defective and the system is no longer under warranty.
To replace one hard drive in an MXe III:
Note: The defective hard drive is indicated by a flashing green Host LED.
Tip: Refer to Table 73 on page 339 for a complete description of LED activity.
1. Release the retaining screw securing the hard drive carrier to the
controller.
2. Slide the defective hard drive out of the hard drive carrier.
3. Remove the four screws securing the hard drive to the hard drive
carrier.
4. Install the new hard drive in the hard drive carrier with the four screws.
Make sure it is correctly oriented (right side up); see Figure 75.
5. Slide the hard drive carrier into the controller.
6. Push to seat the hard drive carrier into the hard drive backplane.
Install and Replace Units
215