To install an APC-CX(i) II Assembly in a CX II/CXi II:
1. Power down the controller and remove the controller cover; see pages
47 and 129.
2. Using diagonal cutters, clip the tie-wrap holding the power cables to
the tie-wrap base. Take care to avoid cutting the cables; see
Figure 61. (Note: Location of tie-wrap base may vary on your
controller.)
3. Remove the APC-CX(i) II Assembly from the anti-static bag.
-
Before seating the assembly in the chassis, connect the following
cables, referring to Figure 62 (page 196) for connector locations.
Only some of the connections are made in this step; the remaining
are made after the assembly is seated. Note that the SATA and
housekeeping cables are keyed for proper connection.
-
SATA power cable to the hard disk drive; (1) in Figure 62 (page
196)
-
6-pin power connector to the APC-CX(i); (2) in Figure 62 (page
196)
-
SATA data cable from hard disk drive to SATA 0 port on the
APC-CX(i) II; (3) in Figure 62 (page 196)
-
one end of the housekeeping signal cable to the APC-CX(i) II; (4)
in Figure 62.
Figure 61: Clipping tie-wrap
Install and Replace Units