Reset
Interpretation
Cause
0x3
Hard reset
0x13
Checkstop reset
(see PPC82XX
manual)
0x43
Watchdog reset
0x83
Power-on reset
0x103
Programmed reset
0x203
Push-button reset
Collect System Logs
Product Support may request logs in the event of a system failure (see
Table 14 below). In the event of a system lockup, go to "Collecting System
Lockup Logs Manually" on page 406.
Linux Software Logs on the MXe Server APC-MXe
The Linux software stores logs in the /var/logs directory. You can view
these logs via the MSL web interface. You need root privileges to view
these logs.
Table 13: System Reset Causes
Root Cause
Unknown reset.
Double bus fault as documented in the
Power PC Manual(s).
The watchdog task was unable to write to
the hardware watchdog. A higher priority
task is running or interrupts are disabled.
This is a software problem.
The system lost AC power.
The system software intentionally
restarted the system.
The front panel reset button was pressed.
Maintenance