Power Up The Controller; Mxe Server - Mitel 3300 Technician's Handbook

3300 ip communications platform communications director release 5.0
Table of Contents

Advertisement

3300 ICP Technician's Handbook
3. Connect a straight-through Ethernet cable (RJ-45) from the controller
leftmost Ethernet port (port 17 on the CXi and CXi II; port 1 on the CX,
CX II, MXe, and MXe Server) and the PC's network interface card
(NIC). When connecting to the AX, either Ethernet port will work.
4. Program the PC's NIC with the following settings:
-
IP Address: 192.168.1.n (where n is a value between 30 and 254)
-
Subnet Mask: 255.255.255.0
Note:For the MXe Server, the controller IP is the System IP address; default
192.168.1.5. Reserve 8 consecutive IP addresses for the MXe Server.

Power Up the Controller

1. Connect the female end of the power cable to the controller, and
secure it with the latch (if provided).
2. Connect the other end of the power cable to a protected outlet. Turn
on power switch (MXe, MXe Server, CX/CXi, and CX II/CXi II). If there
are two power supplies, ensure that both power switches are turned
on. The controller starts up.
Time: The controller can take up to 15 minutes to start-up.
3. Proceed to "Establish Communication with Controller" on page 25

MXe Server

Unlike the other 3300 ICP controllers, the MXe Server arrives complete,
with all of the software pre-installed on the hard disk. This includes the
Mitel Communications Director (MCD) software and the VxWorks virtual
machine. There is still some configuration and licensing work to do before
the MXe Server can be used in your network, though, and the instructions
are provided in this section.
The MXe Server is shipped with an Application Processor Card
(APC-MXe) that runs the MCD call control software. Also included
standard on the MXe Server are the RTC and the E2T cards. All of these
processors must be able to communicate with each other, so IP addresses
must be assigned to all of them.
14

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents