E2T or RTC Processor

Tip: Refer to the 3300 ICP Engineering Guidelines to determine when a
second processor is necessary in the MXe.
Tip: The MXe Server ships with both E2T and RTC as standard equipment.
CAUTION: If you are replacing an RTC in an MXe or MXe
Server running 8.0+ software, you may need to change the
bootline from /partition1/RTC8260 to /partition4/RTC8260.
To add or replace an E2T or RTC processor in an MXe or MXe
Server:
1. Access the main board; see "Accessing the MXe Carrier Board" on
page 163.
2. Tilt the back of the chassis up several inches, reach underneath the
MXe carrier board and then do one of the following:
For the MXe II, disconnect the IDE interconnect cable from the
RTC (host) IDE connector (see Figure 69).
Figure 69: Disconnecting the IDE Interconnect Cable - MXe II/Server
For the MXe III, disconnect the I2C and SATA cables from the hard
drive backplane (or RAID controller if installed), and then
202