Mitel 3300 Technician's Handbook page 216

3300 ip communications platform communications director release 5.0
Table of Contents

Advertisement

3300 ICP Technician's Handbook
3. Remove the screws connecting the bracket to the back of the
controller, then slide the bracket forward and remove it. (Removal is
unnecessary if the drive is installed in the upper bracket position.)
4. Replace the drive with the new one (1) (see Figure 72 on page 206)
and secure it to the bracket (2). (If the bracket was removed, re-install
it and secure it to the back of the controller.) Ensure that the jumpers
on the new drive are set to the Master setting.
5. Connect the power and IDE cables (ribbon cable) to the corresponding
connectors on the hard drive and main board (3). The cables are
keyed for proper connection.
Tip: There are two ribbon cable connectors side by side (shown in black and
blue in Figure 72 on page 206). Ensure that you connect the ribbon cable to
the connector nearest the hard drive. It is shown in blue in the figure.
Figure 72: CX Controller Hard Drive Installation
6. Replace the controller cover.
7. Remount the controller.
206