Mitel 3300 Technician's Handbook page 96

3300 ip communications platform communications director release 5.0
Table of Contents

Advertisement

3300 ICP Technician's Handbook
1. Back up the 3300 ICP database to the Installer PC (page 130).
CAUTION: If you have a Universal NSU with a PRI database,
you may need to convert that database before you begin the
upgrade. Refer to "Converting a PRI Database on a Universal
NSU" on page 138 and the RN for conditions.
2. Install the software on the FTP Server (page 106).
3. Connect the maintenance PC to the controller (page 13).
4. Launch your VT100 emulator communications program.
5. Power up the controller.
6. Stop the controller from booting by responding to the prompt:
-
Press <SPACE><SPACE><SPACE> to stop auto-boot AFTER
countdown starts (Release 5.2 and later)
-
Press any key to stop auto-boot (prior to Release 5.2).
7. At [VXWorks Boot], type c, and press ENTER.
8. For each setting shown in bold (Table 7 below), type the table value,
then press ENTER. For all other settings, press ENTER to accept the
default value.
Tip: The VXWorks parameters are case-sensitive.
Prompt
boot device
processor number 0
host name
file name
86
Table 7: VxWorks Settings
Value
qefcc
(CX(i) II and MXe III)
—or—
motfcc
(all other controllers)
bootHost
Boot_Install
Note
Boot device is Network.
Note: The CX(i) II and MXe III
accept motfcc but automatically
convert it to qefcc on the next
system reboot.
Not used.
Boot location and file name.