Mitel 3300 Technician's Handbook page 269

3300 ip communications platform communications director release 5.0
Table of Contents

Advertisement

Table 38: BRI Connector Pinout (Amphenol 25-pin)
Pin
Signal
1
T1
2
T2
3
T3
4
T4
5
T5
6
T6
7
T7
8
T8
9
T9
10
T10
BRI NSU DIP Switch Settings
Table 39 below shows the settings for the CEPT port DIP switch for the
BRI NSU.
Table 39: CEPT Mode - E1 Port DIP Switch Settings
Switch
Use
1
Tx Ground
2
Rx Ground
Note: This setting is site-dependent. Normally Tx is grounded and Rx is not
grounded, but that depends on which remote connection is grounded. These
switches are used only with the coaxial adapter; leave up (floating) with twisted
pair connection. Not required for RJ-45 connector.
Pin
Signal
11
12
13
14
15
26
27
28
29
30
Setting
Notes
Up: Floating
Not required for RJ-45 connector.
Down: Ground
Up: Floating
Not required for RJ-45 connector
Down: Ground
Hardware Reference
Pin
T11
31
T12
32
T13
33
T14
34
T15
35
R1
36
R2
37
R3
38
R4
39
R5
40
Signal
R6
R7
R8
R9
R10
R11
R12
R13
R14
R15
259