Valve Assembly - Pontiac Grand Prix Service Manual

1969
Table of Contents

Advertisement

WINDSHIELD WIPERS
12A-15
VALVE ASSEMBLY
CA
UTION:
During re-assembly be sure gasket between
housing and valve plate is properly positioned in the
housing and valve plate grooves. Also be sure triple 0
1.
Remove the four
(4)
screws that attach the valve
ring is properly installed between valve body and pipe
assembly to the pump housing.
assembly.
TORQUE SPECIFICATIONS
............................
All specifications are in Lb. In. unless otherwise
Motor tie bolts..
30
specified.
Relay attaching screw (internal)
. . . . . .
Washer pump mounting screws.
...............
18
Pontiac or Tempest Optional System.
30
.............................
Armature adjusting screw jam nut
Crank arm nut.
60
. . . . . . . . . . . . . .
(Tempest or Firebird).
...................
50
Wiper to firewall attaching bolts.
25
Wl PER SPECIFICATIONS
Operating Voltage Pontiac
or Optional Tempest System.
.........
12-14
VDC
Operating Volts Tempest
or Firebird..
..........................
12
VDC
Crank Arm Rotation
(looking at Crank Arm).
.......
.Counterclockwise
Crank Arm Speed (rpms) (No Load):
LO..
.................................
40 Min.
HI..
.................................
70 Min.
Current Draw Recess Park-Tempest
and Grand Prix
Bench Check.
.....
.LO Speed
6.0
Amps. Max.
HI Speed
4.5
Amps. Max.
.
....
Installed in Car.
LO Speed
5.5
Amps. Max.
HI Speed
4.5
Amps. Max.
Stall.
..............
18 Amps. Max.
Current Draw Recess ParklPontiac
. . . . .
Bench Check.
.LO Speed
6.0
Amps. Max.
HI Speed
4.5
Amps. Max.
....
lnstalled in Car.
LO Speed
6.5
Amps. Max.
HI Speed
5.0
Amps. Max.
Stall.
..............
28.0
Amps. Max.
Current Draw-Rectangular-Tempest
......
Bench Check.
LO Speed
4.5
Amps. Max.
HI Speed
3.5
Amps. Max.
...
Installed in Car.
.LO Speed
4.5
Amps. Max.
HI Speed
3.5
Amps. Max.
Stall.
..............
28
Amps. Max.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents