Planet WGSW-52040 Configuration Manual page 477

48-port 10/100/1000base-t + 4-port 100/1000x sfp managed switch
Hide thumbs Also See for WGSW-52040:
Table of Contents

Advertisement

Before configuring layer-3 remote port mirroring, make sure that you have created a GRE tunnel that
connects the source and destination device, and ensure the normal transmitting for GRE tunnel.
The configuration of layer-3 remote port mirror needs to be processed on the source and destination
n devices respectively. Both the source and destination ports are configured on the source and destination
devices, the difference in the following:
1) On Device A, configure the port which you want to monitor as the source port and configure the tunnel
interface as the destination port.
2) On Device C, configure the physical port corresponding to the tunnel interface as the source port and
configure the port that connects the data monitor device as the destination port.
(1) Configure IP addresses
Configure IP address and subnet mask for the interfaces, configuration procedures is omitted.
(2) Configure Device A (the source device)
# Create interface Tunnel1, and configure an IP address and mask for it.
SwitchA(config)#interface tunnel 1
SwitchA(config-if-tunnel1)# tunnel mode gre ip
SwitchA (config-if-tunnel1)#ip address 50.1.1.1 255.255.255.0
# Configure Tunnel1 to operate in GRE tunnel mode, and configure source and destination IP addresses for it.
SwitchA(config-if-tunnel1)# tunnel source 10.1.1.1
SwitchA(config-if-tunnel1)# tunnel destination 40.1.1.1
SwitchA(config-if-tunnel1)# exit
# Configure OSPF protocol.
Figure 61-1:
ERSPAN application
61-48