Ddm Troubleshooting - Planet WGSW-52040 Configuration Manual

48-port 10/100/1000base-t + 4-port 100/1000x sfp managed switch
Hide thumbs Also See for WGSW-52040:
Table of Contents

Advertisement

The last threshold-violation time is Jan 02 11:00:50 2011.
Brief alarm information:
RX loss of signal
RX power low
Detail diagnostic and threshold information:
Realtime Value High Alarm
------------
Temperature(℃) 33
Voltage(V)
Bias current(mA) 3.11
RX Power(dBM) -30.54(A-) 9.00
TX Power(dBM) -1.01
Ethernet 1/22 transceiver threshold-violation information:
Transceiver monitor is disabled. Monitor interval is set to 30 minutes.
The last threshold-violation doesn't exist.

16.4 DDM Troubleshooting

If problems occur when configuring DDM, please check whether the problem is caused by the
following reasons:
Ensure that the transceiver of the fiber module has been inserted fast on the port, or
else DDM configuration will not be shown.
Ensure that SNMP configuration is valid, or else the warning event cannot inform the
network management system.
Because only some boards and box switches support SFP with DDM or XFP with
DDM, ensure the used board and switch support the corresponding function.
When using show transceiver command or show transceiver detail command, it
cost much time due to the switch will check all ports, so it is recommended to query
the monitoring information of the transceiver on the specified port.
Ensure the threshold defined by the user is valid. When any threshold is error, the
transceiver will give an alarm according to the default setting automatically.
Diagnostic
-----------
-----------
70
7.31
10.00
10.30
9.00
16-60
Threshold
Low Alarm
High Warn
------------
0
70
0.00
5.00
0.00
5.00
-25.00(-34)
9.00
-12.05
9.00
Low Warn
---------
0
0.00
0.00
-25.00
-10.00