Minimum Startup Configuration - Fujitsu PRIMERGY GX2460 M1 Upgrade And Maintenance Manual

Table of Contents

Advertisement

Appendix A
14.4

Minimum startup configuration

Field Replaceable Units (FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Component
System board
CPU with CPU heat sink
1 memory module
Front panel module
PSU
Table 4: Minimum startup configuration - components
Cable
Front panel cable
Power cable
Table 5: Minimum startup configuration - cables
"Shutting down the server" on page 40
Ê
"Disconnecting the power cord" on page 41
Ê
Ê Take the system down to its minimum startup configuration.
"Connecting the power cord" on page 53
Ê
Ê Connect a display to the server.
"Switching on the server" on page 54
Ê
240
Notes
no TPM or expansion cards installed
installed in CPU slot CPU 0
installed in DIMM slot P0_UMC3_CH_C0
installed in PSU bay PSU 1
Notes
Upgrade and Maintenance Manual
GX2460 M1

Advertisement

Table of Contents
loading

Table of Contents