Minimum Startup Configuration - Fujitsu PRIMERGY RX4770 M6 Upgrade And Maintenance Manual

Table of Contents

Advertisement

Jumper
JP3
BIOS WP
16.4

Minimum startup configuration

Field Replaceable Units
(FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Component
Top/bottom system
board
2 CPUs with CPU heat
sink
2 memory module
COP
1 PSU
Power distribution board
Table 4: Minimum startup configuration - components
RX4770 M6
Status
Description
Default
BIOS Flash Write Protect enabled
Notes
no TPM, no Dual microSD 64GB Enterprise, no
M.2 SSD, no expansion card including OCP
module is installed
installed in CPU socket CPU1 and CPU socket
CPU2
installed in DIMM slot 1A (CPU1) and in DIMM slot
1G (CPU2)
installed in PSU bay PSU 1
Upgrade and Maintenance Manual
Appendix A
417