Sensor name (Diag. Code)
Sensor Full Toner (DI-6e)
NOTE: Prepare the small paper (10mm x 50mm).
1)
Turn on the power and enter the Diagnostic Mode.
2)
Execute the DI-6e.
3)
Open the Front Door and the Top Cover.
4)
Pull up the right side lever (Blue of the printer.
5)
Remove the drum cartridge.
6)
Check the sensor.
oper.)
Paper
7)
Press the "Cancel" key to stop the test.
8)
Reseat the drum cartridge and set the lever.
9)
Close the Front Door and the Top Cover.
2 - 35
Chapter 2 Operation of Diag.
Confirmation procedure
(NOTE: Take care do not touch the devel-
Operator Panel
Sensor Full Toner
Leg_Sec02_029FA