RRP7.7
SENSOR TNER FULL (PL 7.1.30)
[Removal]
1)
Remove VERTICAL TRANSPORT ASSEMBLY. (RRP 5.3)
2)
Remove connector (P/J126) of SENSOR TNER FULL (PL 7.1.30).
3)
Release two hooks that fixes SENSOR TNER FULL to the main unit and remove SENSOR
TNER FULL.
[Replacement]
1)
Match the two hooks of SENSOR TNER FULL to fitting position and attach it to the main
unit.
2)
Attach connector (P/J126) of SENSOR TNER FULL.
3)
Attach VERTICAL TRANSPORT ASSEMBLY. (RRP 5.3)
Chapter 3 Removal and Replacement Procedures (RRPs)