Network and Security Manager Administration Guide
140
Sends the configlet file to the onsite administrator, who installs the configlet on the
6.
security device at its physical location.
After the onsite administrator installs the configlet and the device has successfully
7.
connected to the management system, the NSM administrator installs the modeled
device configuration on the physical device.
The onsite administrator works locally, at the physical device and performs the following
tasks:
Installs the configlet on a locally connected device.
1.
Runs the Rapid Deployment Wizard.
2.
The RD wizard uses the information in the configlet to establish and authenticate a
secure connection to the NSM Device Server, enabling NSM to begin managing the
device.
NOTE: You cannot activate devices in transparent mode using a configlet.
After the security device has connected to NSM, the NSM administrator can manage the
device exactly like any other security device in NSM.
NOTE: If you delete the security device from the NSM system and then add
the device again, you must also re-create the configlet and install it on the
physical device.
To use rapid deployment:
The device must be running ScreenOS 5.x or later release.
The device must use default factory settings.
The device must be able to reach the Internet using a static IP address, an IP address
assigned with PPPoE, PPPoA, or DHCP.
The device must be modeled in NSM system. For details on modeling a device, see
"Modeling a Device" on page 131.
After you have modeled the device in the management system, you can track its status
using the Device Monitor. Check the device configuration status by holding your mouse
cursor over the device in Device Manager, or by checking the configuration status in Device
Monitor. The status should display "Modeled", indicating that the management system
has modeled the device, but the device is not activated and has not connected.