Sharp MX-4100N Service Manual page 81

Digital full color multifunctional system
Hide thumbs Also See for MX-4100N:
Table of Contents

Advertisement

2)
Enter the simulation 48-1 mode.
3)
Make a normal copy and obtain the copy magnification ratio.
Press [CLOSE] key to shift from the simulation mode to the
copy mode, and make a copy.
4)
Check that the copy magnification ratio is within the specified
range (100 ± 1.0%).
If the copy magnification ratio is within the specified range (100
± 1.0%), the adjustment is completed. If the copy magnification
ratio is not within the specified range, perform the following
procedure.
5)
Change the CCD (MAIN) adjustment value of Simulation 48-1.
When the adjustment value is increased, the copy magnifica-
tion ratio is increased.
When the adjustment value is changed by 1, the copy magnifi-
cation ratio is changed by about 0.1%.
Repeat the procedures 3) - 5) until the copy magnification ratio
is within the specified range (100 ±1.0%).
14-B
Scan image magnification ratio adjustment
(Sub scanning direction) (Document table
mode)
1)
Place a scale on the document table as shown in the figure
below.
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
2)
Enter the simulation 48-1 mode.
3)
Make a normal copy and obtain the copy magnification ratio.
Press [CLOSE] key to shift from the simulation mode to the
copy mode, and make a copy.
Copy magnifi-
cation ratio
(Example 1)
Copy A
(Shorter than
the original)
Scale
(Original)
(Example 2)
Copy B
(Longer than
the original)
4)
Check that the copy magnification ratio is within the specified
range (100 ± 1.0%).
If the copy magnification ratio is within the specified range (100
± 1.0%), the adjustment is completed. If the copy magnification
ratio is not within the specified range, perform the following
procedure.
5)
Change the CCD (SUB) adjustment value of Simulation 48-1.
When the adjustment value is increased, the copy magnifica-
tion ratio in the sub scanning direction is increased.
When the adjustment value is changed by 1, the copy magnifi-
cation ratio is changed by about 0.1%.
Repeat the procedures 3) - 5) until the copy magnification ratio is
within the specified range (100 ±1.0%).
ADJ 15
15-A
15-C
This adjustment must be performed in the following cases:
* When the scan control PWB is replaced.
* When the EEPROM on the scan control PWB is replaced.
* When U2 trouble occurs.
* When the copy magnification ratio is not matched.
* When the RSPF/DSPF is disassembled.
MX-5001N ADJUSTMENTS 5 – 39
(Original dimension - Copy dimension)
Original dimension
10
20
10
20
10
20
Scan image magnification ratio
adjustment (RSPF/DSPF mode)
Scan image magnification ratio adjustment
(Main scanning direction) (RSPF mode)
Scan image magnification ratio adjustment
(Main scanning direction) (DSPF mode)
100%
90
100
110
90
100
110
90
100
110