9)
Remove the cleaner.
10) Use the cleaner to clean the scanning glass (surface).
Maintenance: Clean at every 150K.
11) Use the cleaner to clean the white reference glass.
Maintenance: Clean at every 150K.
12) Close the DSPF unit. Open the upper door, and remove the
screw.
2
1
MX-5001N MAINTENANCE 8 – 45
13) Remove the pawl, and remove the front cabinet.
1
14) Remove the screw. Remove the pawl. Remove the rear cabi-
net.
2
1
15) Open the DSPF unit, and remove the OC mat from the left
edge.
Maintenance: Clean at every 150K.
* When assembling, place the OC mat on the document table
to fit with the reference and close the DSPF unit.